Carbon Dioxide Fire Extinguishers
Carbon Dioxide Fire Extinguishers

Carbon Dioxide Fire Extinguishers

MOQ : 20 Pieces

Carbon Dioxide Fire Extinguishers Specification

  • Mounting Type
  • Wall Mounted
  • Fire Class
  • Class B & C (Flammable liquids and electrical fires)
  • Coverage Area
  • 35 square meter (approximate, depending on capacity)
  • Operating Pressure
  • 5060 bar
  • Fire Extinguisher Type
  • Carbon Dioxide (CO2) Type
  • Connectivity Type
  • Standalone, Non-connected
  • Technology
  • Stored Pressure, Squeeze Grip Operation
  • Coating Type
  • Red Epoxy Polyester Powder Coated
  • Control Type
  • Manual
  • Installation Type
  • Wall Mounted or Portable
  • Features
  • Non-corrosive, No residue, Safe for electrical use
  • Shape
  • Cylinder
  • Working Temperature
  • -20C to +55C
  • Application
  • Industrial, Commercial, Electrical Equipment, Server Rooms, Laboratories
  • Max Flow Rate
  • Varies by capacity (approx. 2.54.5 kg/sec)
  • Capacity
  • 2 kg, 4.5 kg, 6.5 kg, 9 kg (as per model)
  • Diameter
  • 150 mm to 180 mm (varies by model)
  • Pressure
  • 50 60 bar (at 27C)
  • Rechargeable
  • Yes
  • Weight (Full)
  • Approx. 7.5 kg (for 4.5 kg model)
  • Approval Standards
  • ISI Marked, BIS Approved
  • Cylinder Material
  • Seamless Mild Steel/Aluminium
  • Hose Type
  • High Pressure Flexible Discharge Hose with Horn
  • Discharge Duration
  • 820 seconds (depending on capacity)
  • Nozzle Type
  • Non-conductive Discharge Horn
  • Extinguishing Medium
  • 100% Pure Carbon Dioxide Gas
  • Shelf Life
  • 35 years
 

Carbon Dioxide Fire Extinguishers Trade Information

  • Minimum Order Quantity
  • 20 Pieces
  • Supply Ability
  • 4000 Pieces Per Day
  • Delivery Time
  • 1 Days
  • Packaging Details
  • Standard
  • Main Domestic Market
  • All India
  • Certifications
  • ISO and BIS
 

About Carbon Dioxide Fire Extinguishers

Benefited by rich industry experience and knowledge, we are involved in offering our clients a high quality range of Carbon Dioxide Fire Extinguishers. Ideal for residential and industrial projects, these can be used from medium to large sized fires. Due to their long range, the fire extinguishers can attack fire from different angles. These Carbon Dioxide Fire Extinguishers require low maintenance and virtually, does not leak. The purpose of these fire extinguishers is to provide a readily available source to any point.

Features:

  • Excellent performance
  • Damage proof design
  • Easy installation


Certified Safety and Compliance

Each unit meets stringent Indian safety standards, carrying ISI marking and BIS approval for trusted quality. The seamless steel or aluminium cylinder provides robust construction, while the red epoxy polyester powder coating ensures long-term resistance to corrosion even in demanding settings.


Optimal Performance and Ease of Use

Discharge durations between 8 and 20 seconds, squeeze grip operation, and high-pressure flexible hose deliver quick, targeted suppression of fires. The non-conductive discharge horn guarantees operator safety near live electrical equipment. Maintenance is simplified with rechargeable design and a shelf life of 35 years.


Versatile Applications Across Environments

These extinguishers serve diverse requirements, suitable for use in industrial units, laboratories, server rooms, commercial spaces, and on electrical panels. Their residue-free operation helps protect sensitive equipment without cleanup hassles, and they can be easily wall mounted or transported as needed.

FAQs of Carbon Dioxide Fire Extinguishers:


Q: How do I properly use a Carbon Dioxide fire extinguisher?

A: To use the extinguisher, pull the safety pin, aim the discharge horn at the base of the fire, and squeeze the grip handle. Always direct the CO2 in short bursts until the flames are out. Make sure to keep the horn pointed away from your body, as it becomes very cold during use.

Q: What types of fires are these extinguishers best suited for?

A: These extinguishers are designed for Class B and C fires, which include flammable liquid fires (such as oils, solvents, and paints) and electrical fires involving live equipment, making them especially useful in commercial and technical environments.

Q: When should I replace or recharge my CO2 fire extinguisher?

A: Carbon Dioxide extinguishers typically have a shelf life of 35 years. You should recharge the extinguisher after any use or when regular inspections indicate pressure loss, even if it hasnt reached the end of its shelf life.

Q: Where can I install or place these CO2 fire extinguishers?

A: These extinguishers can be wall mounted in visible, easily accessible locations, such as near exits, server rooms, or electrical panels. They are also portable for quick deployment in different areas as needed.

Q: What is the benefit of using CO2 fire extinguishers on electrical equipment?

A: CO2 extinguishers leave no residue and are non-conductive, making them safe for sensitive electrical installations. This prevents damage or contamination, which is a common issue with some other extinguishing agents.

Q: How does the recharge process work for these extinguishers?

A: After discharge or as part of routine maintenance, a licensed service provider should safely relieve any remaining pressure, refill with 100% pure CO2, and conduct a pressure test before resealing and marking the unit.

Q: What safety features ensure operator protection during use?

A: The extinguishers have a non-conductive discharge horn to minimize electrical shock risks, squeeze grip for controlled operation, and a high-pressure, flexible hose for stable handling. Cylinder and components are robustly constructed, meeting ISI and BIS safety standards.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Fire Extinguishers Category

Fire Extinguishers

Fire Extinguishers

Minimum Order Quantity : 20 Pieces

Working Temperature : 30C to +60C

Application : Fire safety and suppression in commercial, residential, and industrial areas

Shape : Cylinder

Coating Type : Red epoxy powder coated

Mechanical Foam Fire Extinguishers

Mechanical Foam Fire Extinguishers

Minimum Order Quantity : 20 Pieces

Working Temperature : 5C to +55C

Application : Industrial, Commercial, Residential, Warehouses, Offices, Factories

Shape : Cylinder

Coating Type : Epoxy Powder Coated

Water Co2 Fire Extinguishers

Water Co2 Fire Extinguishers

Minimum Order Quantity : 20 Pieces

Working Temperature : 5C to 55C

Application : Fire safety for office buildings, warehouses, factories, and industrial sites

Shape : Cylindrical

Coating Type : Powder coated/painted for corrosion resistance

Stored Pressure ABC Fire Extinguishers

Stored Pressure ABC Fire Extinguishers

Minimum Order Quantity : 20 Pieces

Working Temperature : 20C to +55C

Application : Fire Safety (suitable for Class A, B, C fires and electrical fires)

Shape : Cylinder

Coating Type : Epoxy Polyester Powder Coated



Back to top